DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

78Q2132 Просмотр технического описания (PDF) - TDK Corporation

Номер в каталоге
Компоненты Описание
производитель
78Q2132 Datasheet PDF : 36 Pages
First Prev 31 32 33 34 35 36
78Q2132
1/10BASE-TX
HomePNA/Ethernet Transceiver
ELECTRICAL SPECIFICATIONS (continued)
10BASE-T ISOLATION TRANSFORMERS
Two simple isolation transformers are all that are required at the line interface, but transformers with integrated
common-mode choke are recommended for exceeding FCC requirements. This table gives the recommended
line transformer characteristics:
NAME
Turns Ratio
Open-Circuit Inductance
Leakage Inductance
Inter-Winding Capacitance
D.C. Resistance
Insertion Loss
HIPOT
Tx VALUE
1.414 CT : 1 CT ± 5%
350 uH (min)
0.40 uH (max)
12 pF (max)
0.9 (max)
1.1 dB (typ)
1500 Vrms
Rx VALUE
1 CT : 1 CT ± 5%
350 uH (min)
0.40 uH (max)
12 pF (max)
0.9 (max)
1.1 dB (typ)
1500 Vrms
CONDITION
@ 10 mV, 10 kHz
@ 1 MHz (min)
0 – 100 MHz
HomePNA ISOLATION TRANSFORMER
A simple 1:1 isolation transformer with integrated series capacitor in the primary is required at the line interface,
but transformers with integrated common-mode choke are recommended for exceeding FCC requirements. This
table gives the recommended line transformer characteristics:
NAME
Turns Ratio
Open-Circuit Inductance
Leakage Inductance
Inter-Winding Capacitance
D.C. Resistance
Insertion Loss
HIPOT
Series C at line side
VALUE
1 CT : 1 CT ± 5%
140 uH (min)
2.0 uH (max)
6 pF (max)
0.25 (max)
1.1 dB (typ)
2000 Vrms
0.001uF @ 2000v
CONDITION
@ 100 mVRMS, 100 KHz
@ 1 MHz (min)
0 – 100 MHz
32