TLV4906K
Specification
Applied
Magnetic
BOP Field
B RP
VQ
90%
td
tf
td
tr
10%
Figure 6 Timing Diagram
Table 5 Magnetic Characteristics 1)
Parameter
Symbol
Operate point
Release point
Hysteresis
Temperature compensation of
magnetic thresholds
BOP
BRP
BHYS
TC
Repeatability of magnetic
thresholds3)
BREP
1) Over all operating conditions.
2) At 25°C.
3) BREP is equivalent to the noise constant.
Min.
6.2
4.7
0.7
–
Values
Typ. Max.
10.0 13.9
8.5 12.3
1.5 3.0
-350 –
–
20 –
Unit Note / Test Condition
mT
mT
mT
2)
ppm/°C
µTRMS typical value for
ΔΒ/Δt > 12mT/ms
Datasheet
13
Rev. 1.1, 2010-08-02