Philips Semiconductors
Fully integrated DECT transceiver
Product specification
UAA3545
SYMBOL
PARAMETER
CONDITIONS
MIN.
TYP. MAX. UNIT
fi(RF)(max)
fi(RF)(min)
RLRF
GDEM
VDEM
maximum RF input
frequency
minimum RF input
frequency
return loss on matched balanced; note 1
RF input
demodulator gain
mean value of fdev = ±288 kHz
DC level at demodulator fLO = fRF + 864 kHz
outputs RDATAP and
DATAM
−
−
1 880
−
11
15
−
1.6
−
1.3
1 930
−
−
−
−
MHz
MHz
dB
V/MHz
V
Interface logic input and output pins S_DATA, S_CLK, S_EN, R_ON, VCO_ON, SLCCTR and RDATAP
VIH
VIL
Ibias
VOH(RDATAP)
HIGH-level input voltage
LOW-level input voltage)
input bias current
HIGH-level output
voltage (pin RDATAP)
note 6
HIGH or LOW input levels
bit ‘SLIC’ = 1; IOH = 500 µA
VOL(RDATAP) LOW-level output
voltage (pin RDATAP)
bit ‘SLIC’ = 1; IOL = −500 µA
IO(RON)
output drive current
(pin R_ON)
mode 2 or 3; VRON = HIGH level;
VCC − VRON = 0.5 V
ZO(RON)
output impedance
(pin R_ON)
mode 2 or 3; VRON = LOW level
fSCLK(max)
maximum frequency
(pin S_CLK)
tSEN(min)
minimum pulse duration
(pin S_EN)
1.4
−
−0.3
−
−5
−
VCC − 0.4 VCC
−
0
2.5
5
−
6
−
10
−
1
VCC
+0.4
+5
−
0.4
−
−
−
−
V
V
µA
V
V
mA
kΩ
MHz
µs
Notes
1. Measured and guaranteed only on the Philips evaluation board, including Printed-Circuit Board (PCB) and balun filter
with internal slicer.
2. Mean of the values of transmit frequency at VCP/VCOtune = 0.3 and 2.7 V.
3. Measured with VCP/VCOtune = 1.5 V, mean of the values of transmit frequency at VMOD = 0 and 0.5 V.
4. Frequency difference measured during 420 µs with VMOD = 0 (no modulation applied), at least 20 µs after disabling
the synthesizer.
5. Except for three occurrences, as defined in the DECT specification.
6. VIH should never exceed 3.6 V.
2001 Sep 06