PRELIMINARY TECHNICAL DATA
April 2002
For current information contact Analog Devices at 800/262-5643
Interrupts
Table 7. Interrupts
Parameter
Timing Requirements:
tSIR
IRQ2–0 Setup Before CLKIN High1
tHIR
IRQ2–0 Hold After CLKIN High1
tIPW
IRQ2–0 Pulsewidth2
1Only required for IRQx recognition in the following cycle.
2Applies only if tSIR and tHIR requirements are not met.
Min
6
0
2 + tCK
ADSP-21160N
Max
Unit
ns
ns
ns
CLKIN
IRQ2–0
tSIR
tHIR
tIPW
Figure 14. Interrupts
REV. PrB This information applies to a product under development. Its characteristics and specifications are subject to change without notice. Analog
21