µPD4724
ELECTRICAL SPECIFICATIONS FOR THE DRIVERS (TA = –40 to +85 °C and C1 to C5 = 1 µF)
3 V Mode (VCHA = H, VCC = 3.0 to 3.6 V Unless Otherwise Specified)
Parameter
Low Level Input Voltage
High Level Input Voltage
Low Level Input Current
High Level Input Current
Output Voltage
Output Short-Circuit Current
Slew RateNote 1
Propagation Delay TimeNote 1
Output Resistance
Output Transfer Time in Standby State
Output Transfer Time in Standby State
Power On Output Transfer Time
Symbol
Test Conditions
MIN.
VIL
VIH
2.0
IIL
VCC = +3.6 V, VI = 0 V
IIH
VCC = +3.6 V, VI = 3.6 V
VCC = +3.3 V, RL = ∞, TA = 25 °C
VDO
VCC = +3.3 V, RL = 3 kΩ, TA = Topt. ±5.0
VCC = +3.0 V, RL = 3 kΩ, TA = 25 °C ±5.0
ISC
VCC = +3.3 V, to GND
CL = 10 pF, RL = 3 to 7 kΩ
3.0
SR
CL = 2500 pF, RL = 3 to 7 kΩ
3.0
tPHL
RL = 3 kΩ, CL = 2500 pF
tPLH
RO
VCC = VDD = VSS = 0 V
VOUT = ± 2 V
300
tDAZ
RL = 3 kΩ, CL = 2500 pF,Note 2
tDZA
RL = 3 kΩ, CL = 2500 pF,Note 2
tPRA
RL = 3 kΩ, CL = 2500 pF,Note 3
TYP.
MAX.
0.8
–25
1.0
±9.5
±6.0
±40
30
30
2.5
4
10
1
3
1
3
Remark TYP. values are valid only at TA = 25 °C and should be used for reference only.
5 V Mode (VCHA = L, VCC = 5.0 V ±10 % Unless Otherwise Specified)
Parameter
Low Level Input Voltage
High Level Input Voltage
Low Level Input Current
High Level Input Current
Output Voltage
Output Short-Circuit Current
Slew RateNote 1
Propagation Delay TimeNote 1
Output Resistance
Output Transfer Time in Standby State
Output Transfer Time in Standby State
Power-On Output Transfer Time
Symbol
Test Conditions
MIN.
VIL
VIH
2.0
IIL
VCC = +5.5 V, VI = 0 V
IIH
VCC = +5.5 V, VI = 5.5 V
VCC = +5.0 V, RL = ∞, TA = 25 °C
VDO
VCC = +5.0 V, RL = 3 kΩ, TA = Topt. ±6.0
VCC = +4.5 V, RL = 3 kΩ, TA = Topt. ±5.0
ISC
VCC = +5.0 V, to GND
CL = 10 pF, RL = 3 to 7 kΩ
4.0
SR
CL = 2500 pF, RL = 3 to 7 kΩ
4.0
tPHL
RL = 3 kΩ, CL = 2500 pF
tPLH
RO
VCC = VDD = VSS = 0 V
300
VOUT = ± 2 V
tDAZ
RL = 3 kΩ, CL = 2500 pF,Note 2
tDZA
RL = 3 kΩ, CL = 2500 pF,Note 2
tPRA
RL = 3 kΩ, CL = 2500 pF,Note 2
TYP.
MAX.
0.8
–40
1.0
±9.7
±40
30
30
2
4
10
0.5
1
0.5
1
Remark TYP. values are valid only at TA = 25 °C and should be used for reference only.
Unit
V
V
µA
µA
V
V
V
mA
V/µs
V/µs
µs
Ω
µs
ms
ms
Unit
V
V
µA
µA
V
V
V
mA
V/µs
V/µs
µs
Ω
µs
ms
ms
7