Philips Semiconductors
Cordless telephone line interface
Objective specification
UBA1706
General purpose switches (pins SWI1 and SWI2; bits
SWC1 and SWC2)
The UBA1706 is equipped with two general purpose
open-collector switches, which short circuit pins SWI1 and
SWI2 to ground. These switches are controlled by bits
SWC1 and SWC2, respectively, and have an operating
voltage limited to 12 V. The outputs have to be current
biased. For a bias current between 2 and 20 mA, the
AC impedance is 30 maximum.
Serial interface (pins DATA, CLK and EN)
A simple 3-wire unidirectional serial bus is used to program
the circuit. The three wires of the bus are EN, CLK and
DATA. The data sent to the device is loaded in bursts
framed by EN. Programming clock edges (falling edges)
and their appropriate data bits are ignored until EN goes
HIGH. The programmed information is loaded into the
addressed register when EN returns to LOW or left
open-circuit.
During normal operation, EN should be kept LOW. Only
the last seven bits serially clocked into the device are
retained within the programming register.
Additional leading bits are ignored and no check is made
on the number of clock pulses. New programming data can
always be captured during global power-down (bit PD at
logic 1).
Data is entered with the most significant bit first. The
leading six bits make up the data field (bits D0 to D5) while
the trailing two bits are the address field (bits ADO and
AD1). The first bit entered is D5, the last bit AD0. This
organisation allows the transmission of only the number of
bits of the addressed register.
Figure 13 shows the serial timing diagram. Table 1 gives
the list of registers.
When the supply voltage VCC drops below 2.5 V, all
register files are set to the initial state (see Table 1)
defined by the power-up reset. At start-up, the circuit is in
power-down mode.
When the IC is used in a noisy environment, it is advised
to periodically refresh the content of registers.