Table 5. State transitions forced by EN and STBN (node configuration)
indicates the action that initiates a transaction; 1 and 2 are the consequences of a transaction.
Transition Direction to Transition Pin
from mode mode
number
STBN
EN
Normal
Receive-only 1
H
L
Flag
UVVIO
cleared
UVVBAT
cleared
UVVCC
cleared
PWON
cleared
Wake
cleared
Note
Go-to-sleep 2
L
H
cleared
cleared
cleared
cleared
cleared
Standby
3
L
L
cleared
cleared
cleared
cleared
cleared
[1]
Receive-only Normal
4
H
H
cleared
cleared
cleared
X
X
Go-to-sleep 5
L
H
cleared
cleared
cleared
X
X
Standby
6
L
L
cleared
cleared
cleared
X
X
Standby
Normal
7
H
H
cleared
cleared
2 cleared X
1 cleared
[2][3]
Receive-only 8
H
L
cleared
cleared
2 cleared X
1 set
[2][3]
Go-to-sleep 9
L
H
cleared
cleared
X
X
X
Go-to-sleep Normal
10
H
H
cleared
cleared
cleared
X
1 cleared
[2][4]
Receive-only 11
H
L
cleared
cleared
cleared
X
1 set
[2][4]
Standby
12
L
L
cleared
cleared
X
X
X
[4]
Sleep
13
L
H
cleared
cleared
X
X
cleared
[5]
Sleep
Normal
14
H
H
2 cleared 2 cleared 2 cleared X
1 cleared
[2][3]
Receive-only 15
H
L
2 cleared 2 cleared 2 cleared X
1 set
[2][3]
[1] STBN must be set to LOW 60 µs after EN.
[2] Positive edge on pin STBN sets the wake flag. In the case of a transition to Normal mode the wake flag is immediately cleared.
[3] Setting the wake flag clears the UVVIO, UVVBAT and UVVCC flag.
[4] Hold time of go-to-sleep is less than the minimum hold time.
[5] Hold time of go-to-sleep becomes greater than the minimum hold time.