DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

SX1233 Просмотр технического описания (PDF) - Semtech Corporation

Номер в каталоге
Компоненты Описание
производитель
SX1233 Datasheet PDF : 81 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
ADVANCED COMMUNICATIONS & SENSING
FSTEP
FRC
BRF
BRO
FDA
Frequency synthesizer step
RC Oscillator frequency
Bit rate, FSK
Bit rate, OOK
Frequency deviation, FSK
FSTEP = FXOSC/219
After calibration
Programmable
Programmable
Programmable
FDA + BRF/2 =< 500 kHz
SX1233
DATASHEET
-
61.0
-
Hz
-
62.5
-
kHz
1.2
-
600 kbps
1.2
-
32.768 kbps
0.6
-
300 kHz
2.4.3. Receiver
All receiver tests are performed with RxBw = 10 kHz (Single Side Bandwidth) as programmed in RegRxBw, receiving a
PN15 sequence with a BER of 0.1% (Bit Synchronizer is enabled), unless otherwise specified. The LNA impedance is set
to 200 Ohms, by setting bit LnaZin in RegLna to 1. Blocking tests are performed with an unmodulated interferer. The
wanted signal power for the Blocking Immunity, ACR, IIP2, IIP3 and AMR tests is set 3 dB above the nominal sensitivity
level.
Table 6 Receiver Specification
Symbol
RFS_F
RFS_O
CCR
ACR
BI
AMR
IIP2
Description
Conditions
Min
FSK sensitivity, highest LNA gain FDA = 5 kHz, BR = 1.2 kb/s
-
FDA = 40 kHz, BR = 38.4 kb/s
-
FDA= 250 kHz, BR = 500 kb/s
-
FDA= 150 kHz, BR = 600 kb/s
-
FDA = 5 kHz, BR = 1.2 kb/s *
-
OOK sensitivity, highest LNA gain BR = 4.8 kb/s
-
Co-Channel Rejection
Adjacent Channel Rejection
-13
Offset = +/- 25 kHz -
Offset = +/- 50 kHz 37
Blocking Immunity
Offset = +/- 1 MHz -
Offset = +/- 2 MHz -
Offset = +/- 10 MHz -
Blocking Immunity
Wanted signal at sensitivity
+16dB
Offset = +/- 1 MHz -
Offset = +/- 2 MHz -
Offset = +/- 10 MHz -
AM Rejection , AM modulated
interferer with 100% modulation
depth, fm = 1 kHz, square
Offset = +/- 1 MHz -
Offset = +/- 2 MHz -
Offset = +/- 10 MHz -
2nd order Input Intercept Point
Unwanted tones are 20 MHz
above the LO
Lowest LNA gain -
Highest LNA gain -
Typ
-118
-105
- 97
- 92
Max Unit
- dBm
- dBm
- dBm
- dBm
-120
- dBm
-112 -109 dBm
-10
- dB
42
- dB
42
- dB
-45
- dBm
-40
- dBm
-32
- dBm
-36
- dBm
-33
- dBm
-25
- dBm
-45
- dBm
-40
- dBm
-32
- dBm
+75
- dBm
+35
- dBm
Rev 3.April 2010
Page 13
www.semtech.com

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]