CERAMIC SURGE ABSORBERS (VARISTORS)
SVC
■ Application notes
1. Overcurrent protection
When surges exceed the rating for the SVC, short-circuits or
damages can be expected. Take following precautions.
2.Installation
① When operated at location near heating element or exp-
osed to direct sun light, confirm that the the ambient
temparature range.
② When operated in dusty or dirty locations, or exposed to
corrosive atomospheres, or where metallic powders or salt
can be expected, be sure to mount within a protective enclo-
sure.
3. Molding
When shielding the SVC in a resin molding, take a note of the
materials used and temperature, since they influence the
reliability. For further information please contact SAMWHA
4.Current, power and energy rating vs, temperature
① Connect the SVC at a position nearer to the equipment
than the overcurrent protection device“”(fuse, MCCB) as is
shown in the diagram.
When the SVC is shorted, the overcurrent protection device
”operates (trips or blow off the fuse).
② If the overcurrent protection device“”can not be in-
stalled in“”position, connect a fuse at“”position. Select
fuse rated current for the SVC referring to the following table.
SVC
05A
05B
Applicable fuse
rated current(A) 1 to 2
07A 10A
14A
20A
07B 10B
14B
20B
2 to 3 3 to 5 3 to 10 5 to 15
③ When“Z2”SVC is connected between the equipment and
ground install an ELCB (Earth Leakage Circuit Breaker). If
not possible, connect a fuse or thermal fuse at“”position.
5. Electrical Characteristics
Operating ambient temperature
Storage temperature
Voltage temperature coefficient
Insulation resistance(at500V)
-40℃ to + 85℃
-40℃ to + 125℃
-0.05%℃
Over 1000MΩ
■ Recognized standards
Standard
Date
Content
UL 1449 93.03.03
Transient Voltage
surge suppressors
UL
UL 1414 88.05.10
UL 497B 93.07.06
CAS
C22.2
NO.1-M
1981
93.07.27
ISO 9002
94.12.15
Across-The-Line
Components
Protectors for data
communication
and fire alarm circuirt
Varistor for Across
-The-Line use as
transient protection
on 120Vac system
Applicable SVC series
Cord connected
and Direct Plug in
Type Equipment
05Series
07Series
10Series
14Series
20Series
Pemanently
connected type
equipment
125V AC
250V AC
10Series
14Series
20Series
SVC 201D - □A
~SVC 391D - □A
SVC 391D - □A
~SVC 182D - □A
SVC 180D - □~SVC 821D - □
File No.
E151195
E97754
E154171
125V AC
SVC 201D - □A
~SVC 182D - □A
LR78923
KRQ-007/94
58