Table 11. AC timing requirements
Symbol
Parameter
Min
Typ
Max
Unit
tCLK
Data clock period
25
-
tWHCLK
Duration of CLK pulse at high level
10
-
tWLCLK
Duration of CLK pulse at low level
10
-
tSDAT
Set-up time of data input before low to high clock
transition
5
-
tHDAT
Hold-time of data input after low to high clock
transition
5
-
tHSTB
Hold-time of STB after low to high clock transition
5
-
tSTB
STB low level pulse duration
10
-
tSSTB
STB set-up time before CLK rise
5
-
-