STA016T
2 HOST REGISTERS
The following table gives a description of STA016 register list.
The STA016 device includes 256 I2C registers. In this document, only the user-oriented registers are described.
The undocumented registers are reserved or unused. These registers must never be accessed (in Read or in
Write mode). The Read-Only registers must never be written
We can split the data flux in different time periods (see following diagram) meanwhile host registers can be read
or written :
s DWT : During Whole Time (at any time during process).
s DEC : During External Config (period between RUN=2 and RUN=1).
s DBO : During Boot (period between RUN=0 and RUN=2).
s ABO : After BOot (period after RUN=1).
s AEC : After External Config (period after RUN=2).
s EDF : Every Decoded Frame (each time a frame has been decoded).
s EDB : Every Decoded Block (each time a block has been decoded).
SOFT_RESET = 1
CK_CMD = 0
block1
block2
block1
HR RUN==0 RUN==2 RUN==1 frame1
frame1
frame2
time
DBO
DEC
D01AU1260
DWT
EDB
EDB
EDF
ABO
AEC
EDB
9/45