Philips Semiconductors
9 V VHF, hyperband and UHF
mixer/oscillator for TV and VCR 3-band tuners
Product specification
TDA5630;
TDA5631
signal
handbook, full pagewidth50 Ω source
e
Vmeas V
50 Ω
50 Ω
RMS
voltmeter
AC
HYBRID
BD
BIN1
(CIN1) IFOUT1
Vi D.U.T.
BIN2
(CIN2)
IFOUT2
TR
Vo
2x5
turns
2 V'meas
turns
N1/N2 = 5
spectrum
analyzer
50 Ω
MBH048
Loss of the hybrid: 0.8 to 1 dB depending on frequency.
Vi = Vmeas − loss of the hybrid.
Vo = V’meas + 15.4 dB (transformer ratio N1/N2 = 5 and transformer loss).
Gv = 20 log (Vo/Vi) = 20 log (V’meas/Vmeas) + 15.4 dB + loss of the hybrid.
Fig.8 Gain measurement in bands B and C.
handbook, full pagewidth
NOISE
SOURCE
AC
HYBRID
50 Ω
BD
BIN1
(CIN1)
IFOUT1
D.U.T.
BIN2
(CIN2) IFOUT2
TR
NOISE
METER
2x5
turns
2
turns
N1/N2 = 5
MBH049
Loss of the hybrid: 0.8 to 1 dB depending on frequency.
NF = NFmeas − loss of the hybrid.
Fig.9 Noise figure measurement in bands B and C.
1996 Mar 21
12