Functional Description
3.4 Circuit Description
3.4.1 General Description
The PMB 2349 consists of two fully programmable PLLs, one for the RF and
one for the IF frequency range. Each PLL contains a high frequency dual mod-
ulus prescaler, an A- and a N-counter with dual modulus control logic, a refer-
ence- (R-) counter, and a phase detector with charge pump output. The two
synthesizers are controlled via the common serial 3-wire interface.
The reference frequency is applied at the common RI-input and divided by the
R-counter of each PLL. Its maximum value is 45 MHz. The RF and IF input fre-
quencies will be divided by the corresponding prescalers with a programmable
32/32 or 64/65 (RF) and 8/9 or 16/17 (IF) divide ratio and the following program-
mable A/N-counters. The maximum RF frequency value is 2.8 GHz and 600
MHz for the IF frequency.
The phase and frequency detectors with the charge pumps have a linear oper-
ating range without a dead zone for very small phase deviations.
The multifunctional output port LD/MFO can be programmed as lock detector
and general purpose output.
3.4.2 Programming
Programming of the IC is done via the serial data interface. The content of the
bus telegram (serial data format) is assigned to the functional units according
to the address.
The most significant bit (MSB) of the serial data formats is shifted first.
The short control data format allows a fast PD-current change.
The long control data format allows the programming of asynchronous or syn-
chronous data acquisition of PLL1 (RF), 4 different PD-output current modes for
the PLL1 and 1 PD-output current modes for PLL2, polarity setting of the PD-
output signals, 2 standby modes, charge pump pulse width and the prescaler
divide ratio.
The A/N-counter data format of PLL1 contains the A/N-counter value.. The data
format of PLL2 comprise the counter values as well.
The R-counter data format contains the R-counter values.
The PLL1 (RF) of PMB 2349 offers the possibility of synchronous counter and
charge pump current programming to avoid phase errors at the phase detector
when R- and A-/N-counter are programmed one after another or the charge
pump current is altered.