7.16 Reset function
The PCF2113x automatically initializes (resets) when power is turned on. The chip executes a reset sequence, including
a ‘clear display’, requiring 165 oscillator cycles. After the reset the chip has the state shown in Table 3.
Table 3 State after reset
STEP
1
2
3
4
5
6
7
8
9
10
11
FUNCTION
CONTROL BIT STATE
CONDITIONS
clear display
entry mode set
I/D = 1
+1 (increment)
S=0
no shift
display control
D=0
display off
C=0
cursor off
B=0
cursor character blink off
function set
DL = 1
8-bit interface
M=0
1-line display
H=0
normal instruction set
SL = 0
MUX 1 : 18 mode
default address pointer to DDRAM; the Busy Flag (BF) indicates the busy state (BF = 1) until
initialization ends; the busy state lasts 2 ms; the chip may also be initialized by software;
see Tables 17 and 18
icon control
IM = 0; IB = 0; DM = 0
icons, icon blink and direct
mode disabled
display/screen configuration
L = 0; P = 0; Q = 0
default configurations
VLCD temperature coefficient
set VLCD
I2C-bus interface reset
TC1 = 0; TC2 = 0
VA = 0; VB = 0
default temperature coefficient
VLCD generator off
Set HVgen stages
S1 = 1; S0 = 0
VLCD generator voltage
multiplier set at factor 4