MN838898
6.6 Switching Input Formats
The following timing chart summarizes the relationships between changes in input format
and the subsequent changes in output.
FY
Start pulse inputs
STHR (RL = High)
STHL (RL = Low)
MODE2
LD
Valid input data
Binary data input
Gray scale data input
YX1 to 120,
YY1 to 120,
YZ1 to 120
Binary data output
Figure 6.6.1 Switching Formats (1/2)
Gray scale
data output
The LSI drives the output pins at high-impedance for one FY cycle when changing
output formats.
FY
LD
YX1 to 120, Binary data output
YY1 to 120, (or gray scale
Hi-Z
YZ1 to 120 data output)
Binary data output
(or gray scale
data output)
Output switching
interval
Figure 6.6.2 Switching Formats (2/2)
SDF00030AEM
7