MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
Table 8 MBM29DL800TA/BA Command Definitions
Command
Sequence
Bus
Write
Cycles
First Bus Second Bus Third Bus
Write Cycle Write Cycle Write Cycle
Fourth Bus
Read/Write
Cycle
Fifth Bus
Write Cycle
Sixth Bus
Write Cycle
Req’d Addr. Data Addr. Data Addr. Data Addr. Data Addr. Data Addr. Data
Word
Read/Reset
1 XXXH F0H — — — — — — — — — —
Byte
Word
555H
2AAH
555H
Read/Reset
3
AAH
55H
F0H RA RD — — — —
Byte
AAAH
555H
AAAH
Word
555H
2AAH
(BA)
555H
Autoselect
3
AAH
55H
90H — — — — — —
Byte
AAAH
555H
(BA)
AAAH
Program
Word
555H
2AAH
555H
4
AAH
55H
A0H PA PD — — — —
Byte
AAAH
555H
AAAH
Word
555H
2AAH
555H
555H
2AAH
555H
Chip Erase
6
AAH
55H
80H
AAH
55H
10H
Byte
AAAH
555H
AAAH
AAAH
555H
AAAH
Word
555H
2AAH
555H
555H
2AAH
Sector Erase
6
AAH
55H
80H
AAH
55H SA 30H
Byte
AAAH
555H
AAAH
AAAH
555H
Erase Suspend 1 BA B0H — — — — — — — — — —
Erase Resume
1 BA 30H — — — — — — — — — —
Set to
Fast Mode
Word
Byte
3
555H
2AAH
555H
AAH
55H
20H
AAAH
555H
AAAH
Fast
Program *1
Word
Byte
2
XXXH
A0H PA
XXXH
PD
Reset from Word
Fast Mode *1 Byte
2
BA
BA
90H
XXXH
XXXH
F0H
*3
Extended Word
Sector
4 XXXH 60H SPA 60H SPA 40H SPA SD — — — —
Protect*2
Byte
*1: This command is valid while Fast Mode.
*2: This command is valid while RESET=VID.
*3: This data "00H" is also acceptable.
Notes: 1. Address bits A12 to A18 = X = “H” or “L” for all address commands except or Program Address (PA), Sector
Address (SA), and Bank Address (BA).
2. Bus operations are defined in Tables 2 and 3.
3. RA = Address of the memory location to be read
PA = Address of the memory location to be programmed
Addresses are latched on the falling edge of the write pulse.
SA = Address of the sector to be erased. The combination of A18, A17, A16, A15, A14, A13, and A12 will
uniquely select any sector.
BA = Bank Address (A16 to A18)
4. RD = Data read from location RA during read operation.
PD = Data to be programmed at location PA. Data is latched on the falling edge of write pulse.
5. SPA =Sector address to be protected. Set sector address (SA) and (A6, A1, A0) = (0, 1, 0).
SD = Sector protection verify data. Output 01H at protected sector addresses and output 00H at
unprotected sector addresses.
6. The system should generate the following address patterns:
Word Mode: 555H or 2AAH to addresses A0 to A11
Byte Mode: AAAH or 555H to addresses A–1 and A0 to A11
7. Both Read/Reset commands are functionally equivalent, resetting the device to the read mode.