DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MAX6647 Просмотр технического описания (PDF) - Maxim Integrated

Номер в каталоге
Компоненты Описание
производитель
MAX6647 Datasheet PDF : 16 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
+145°C Precision SMBus-Compatible Remote/
Local Sensors with Overtemperature Alarms
Table 5. Command-Byte Bit Assignments
REGISTER
RLTS
RRTE
RSL
RCL
RCRA
RLHN
RLLI
RRHI
RRLS
WCA
WCRW
WLHO
WLLM
WRHA
WRLN
OSHT
REET
RIET
RWOE
RWOI
HYS
QUEUE
ADDRESS
00h
01h
02h
03h
04h
05h
06h
07h
08h
09h
0Ah
0Bh
0Ch
0Dh
0Eh
0Fh
10h
11h
19h
20h
21h
22h
FEh
FFh
POR STATE
0000 0000
0°C
0000 0000
0°C
N/A
0000 0000
0000 0111
0101 0101
+85°C
0000 0000
0°C
0101 1111
+95°C
0101 0101
+85°C
0000 0000
0°C
N/A
N/A
N/A
N/A
N/A
N/A
N/A
0000 0000
0°C
0000 0000
0°C
0111 1101
+125°C
0101 0101
+85°C
0101 0101
+85°C
0000 1010
10°C
1000 0110
0100 1101
0101 1001
FUNCTION
Read local (internal) temperature
Read remote (external) temperature
Read status byte
Read configuration byte
Read conversion rate byte
Read local (internal) ALERT high limit
Read local (internal) ALERT low limit
Read remote (external) ALERT high limit (MAX6646/MAX6647)
Read remote (external) ALERT high limit (MAX6649)
Read remote (external) ALERT low limit
Write configuration byte
Write conversion rate byte
Write local (internal) ALERT high limit
Write local (internal) ALERT low limit
Write remote (external) ALERT high limit
Write remote (external) ALERT low limit
One-shot
Read remote (external) extended temperature
Read local (internal) extended temperature
Read/write remote (external) OVERT limit (MAX6646/MAX6647)
Read/write remote (external) OVERT limit (MAX6649)
Read/write local (internal) OVERT limit
Overtemperature hysteresis
Fault queue
Read manufacture ID
Read revision ID
Table 6. Configuration-Byte Bit Assignments (03h)
BIT
7 (MSB)
6
5 to 0
NAME
MASK
RUN
RFU
POR STATE
0
0
0
FUNCTION
Masks ALERT interrupts when set to 1.
Standby mode control bit; if set to 1, standby mode is initiated.
Reserved.
Conversion Rate Byte
The conversion rate register (Table 8) programs the time
interval between conversions in free-running autonomous
mode (RUN = 0). This variable rate control can be used
to reduce the supply current in portable-equipment appli-
cations. The conversion rate byte’s POR state is 07h or
4Hz. The MAX6646/MAX6647/MAX6649 look only at the 3
LSBs of this register, so the upper 5 bits are “don’t care”
bits, which should be set to zero. The conversion rate tol-
erance is ±25% at any rate setting.
Valid A/D conversion results for both channels are avail-
able two total conversion times (250ms nominal, 312ms
maximum) after initiating a conversion, whether conver-
sion is initiated through the RUN bit, one-shot com-
mand, or initial power-up. Changing the conversion rate
can also affect the delay until new results are available.
10

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]