High-Accuracy, High-Side Current Monitors
in SOT23
ELECTRICAL CHARACTERISTICS (continued)
(VBIAS = 5V, GND = 0V, REF = Open, VOUT = 0V (MAX4004), CLAMP = Open, TA = -40°C to +85°C. Typical values are at TA = +25°C,
unless otherwise noted.) (Note 1)
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
Output Clamp Voltage
Output Clamp Leakage
MAX4004 Current Gain
MAX4006
Transimpedance Gain
Power-Supply Rejection
Ratio (PSRR)
Power-Up Settling Time
VOUT -
VCLAMP
IOUT/IREF
VOUT/IREF
(∆IOUT/IOUT)
/∆VBIAS
(∆VOUT/VOUT)
/∆VBIAS
tS
VCLAMP = 0 to 22V
IREF = 250nA
IREF = 2.5mA
IREF = 10mA, VBIAS = 12V
IREF = 250nA
IREF = 2.5mA
IREF = 10mA, VBIAS = 12V
MAX4004:
IREF = 250nA
VBIAS = 2.7V to 22V IREF = 1mA
MAX4006:
VBIAS = 2.7V to 22V
IREF = 1mA
IOUT settles within 0.1%, IREF = 250nA
CIN = 10nF between
REF and GND
IREF = 2.5mA
0.09
0.094
0.9
0.95
0.6
1
0.099
0.095
0.098
0.995
0.998
0.992
50
50
50
7.5
90
0.11
0.106
V
pA
mA/mA
1.1
1.05
V/mA
1000
1000
1000
ppm/V
ms
µs
Note 1: All devices are 100% tested at room temperature (TA = +25°C). All temperature limits are guaranteed by design.
_______________________________________________________________________________________ 3