DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

LS4699-0R Просмотр технического описания (PDF) - Power-One Inc.

Номер в каталоге
Компоненты Описание
производитель
LS4699-0R
Power-One
Power-One Inc. Power-One
LS4699-0R Datasheet PDF : 27 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
Cassette Style
100 Watt AC-DC Converters
S Series PFC
Immunity to Environmental Conditions
Table 9: Environment specifications
Test method
Ca Damp heat
steady state
Ea Shock
(half-sinusoidal)
Eb Bump
(half-sinusoidal)
Standard
IEC/DIN IEC 60068-2-3
MIL-STD-810D section 507.2
IEC/EN/DIN EN 60068-2-27
MIL-STD-810D section 516.3
IEC/EN/DIN EN 60068-2-29
MIL-STD-810D section 516.3
Test conditions
Temperature:
Relative humidity:
Duration:
Acceleration amplitude:
Bump duration:
Number of bumps:
Acceleration amplitude:
Bump duration:
Number of bumps:
40 ±2 °C
93 +2/-3 %
56 days
100 gn = 981 m/s2
6 ms
18 (3 each direction)
40 gn = 392 m/s2
6 ms
6000 (1000 each direction)
Status
Unit not
operating
Unit
operating
Unit
operating
Fc Vibration
(sinusoidal)
IEC/EN/DIN EN 60068-2-6
Acceleration amplitude:
Frequency (1 Oct/min):
Test duration:
0.35 mm (10...60 Hz)
5 gn = 49 m/s2 (60...2000 Hz)
10...2000 Hz
7.5 h (2.5 h each axis)
Unit
operating
Fn Vibration
broad band
random
(digital dontrol)
IEC 60068-2-64
DIN 40046 part 23
MIL-STD-810D section 514.3
Acceleration spectral density: 0.05 gn2/Hz
Frequency band:
5...500 Hz
Acceleration magnitude:
Test duration:
4.97 gn rms
3 h (1 h each axis)
Unit
operating
Kb Salt mist, cyclic IEC/EN/DIN IEC 60068-2-52 Concentration:
(sodium chloride
Duration:
NaCl solution)
Storage:
Storage duration:
Number of cycles:
5% (30°C)
2 h per cycle
40°C, 93% rel. humidity
22 h per cycle
3
Unit not
operating
Table 10: Temperature specications, values given are for an air pressure of 800...1200 hPa (800...1200 mbar)
Temperature
Characteristics
TA Ambient temperature
TC Case temperature
TS Storage temperature
Conditions
U i min...U i max
I o = 0...I o nom
Not operational
Standard -7
min
max
25
71
25
95
40
100
Option -9
min
max
Unit
40
71
°C
40
95
55
100
Table 11: MTBF
Values at Specied
Case Temperature
MTBF 1
Type
LS 4000/5000
1 Calcualted in accordance with MIL-HDBK217F.
Ground Benign
40 °C
514'000
Ground Fixed
40 °C
70 °C
88'000
38'000
Ground Mobile Unit
50 °C
35'000
h
Edition 01/01.2001