DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

82C54 Просмотр технического описания (PDF) - Intersil

Номер в каталоге
Компоненты Описание
производитель
82C54 Datasheet PDF : 24 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
82C54
Counter will be loaded with new count on the next CLK pulse
and counting will continue from there.
CW = 1A LSB = 3
WR
CLK
GATE
OUT
NNN
NN
0
3
0
2
0
1
0 FF 0
0 FF 3
CW = 1A LSB = 3
WR
CLK
GATE
OUT
NN N NN
N
0
3
0
2
0
3
0
2
0 0 FF
1 0 FF
CW = 1A LSB = 3
WR
LSB = 5
CLK
GATE
OUT
N
N
N
N
N
0
3
00
21
0 FF FF 0
0 FF FE 5
0
4
FIGURE 14. MODE 5
Operation Common To All Modes
Programming
When a Control Word is written to a Counter, all Control
Logic, is immediately reset and OUT goes to a known initial
state; no CLK pulses are required for this.
Gate
The GATE input is always sampled on the rising edge of
CLK. In Modes 0, 2, 3 and 4 the GATE input is level
sensitive, and logic level is sampled on the rising edge of
CLK. In modes 1, 2, 3 and 5 the GATE input is rising-edge
sensitive. In these Modes, a rising edge of Gate (trigger)
sets an edge-sensitive flip-flop in the Counter. This flip-flop is
then sampled on the next rising edge of CLK. The flip-flop is
reset immediately after it is sampled. In this way, a trigger
will be detected no matter when it occurs - a high logic level
does not have to be maintained until the next rising edge of
CLK. Note that in Modes 2 and 3, the GATE input is both
edge-and level-sensitive.
Counter
New counts are loaded and Counters are decremented on
the falling edge of CLK.
The largest possible initial count is 0; this is equivalent to 216
for binary counting and 104 for BCD counting.
The counter does not stop when it reaches zero. In Modes 0,
1, 4, and 5 the Counter “wraps around” to the highest count,
either FFFF hex for binary counting or 9999 for BCD
counting, and continues counting. Modes 2 and 3 are
periodic; the Counter reloads itself with the initial count and
continues counting from there.
SIGNAL
STATUS
MODES
LOW OR
GOING LOW
RISING
HIGH
0 Disables Counting
-
Enables Counting
1
-
1) Initiates
-
Counting
2) Resets output
after next clock
2 1) Disables
Initiates Counting Enables Counting
counting
2) Sets output
immediately high
3 1) Disables
Initiates Counting Enables Counting
counting
2) Sets output
immediately high
4 1) Disables
Counting
-
Enables Counting
5
-
Initiates Counting
-
FIGURE 15. GATE PIN OPERATIONS SUMMARY
MODE
MIN COUNT
MAX COUNT
0
1
0
1
1
0
2
2
0
3
2
0
4
1
0
5
1
0
NOTE: 0 is equivalent to 216 for binary counting and 104 for BCD
counting.
FIGURE 16. MINIMUM AND MAXIMUM INITIAL COUNTS