HAL 1820
DATA SHEET
Symbol
Parameter
Pin No.
SensLife
Sensitivity Drift (beside
temperature drift)1)
BOFFSET
Magnetic offset
3
BOFFSET Magnetic offset drift over 3
Temperature Range
BOFFSET(T) BOFFSET
(25 °C)
BHysteresis Magnetic Hysteresis1)
3
1) Guaranteed by design
Values
Min. Typ. Max.
2
2 0
2
300 0
300
Unit Test Conditions
%
TJ = 25 °C; after tem-
perature cycling and
over life time
mT B = 0 mT, TA = 25 °C
µT B = 0 mT, RANGE =
20 mT, Sens = 100
mV/mT
20 0
20
µT Range = 40 mT
1.03
1.02
1.01
1.00
0.99
1.001
0.993
ideal 200 ppm/k
least-square-fit straight-line of
normalized measured data
measurement example of real
sensor, normalized to achieve a
value of 1 of its least-square-fit
straight-line at 25 °C
0.98
-50 -25 -10 0
25 50 75 100 125 150 175
temperature [°C]
Fig. 3–7: Definition of Sensitivity Error ES.
20
July 3, 2013; DSH000158_003EN
Micronas