DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

B72225T4141K101 Просмотр технического описания (PDF) - EPCOS AG

Номер в каталоге
Компоненты Описание
производитель
B72225T4141K101
Epcos
EPCOS AG Epcos
B72225T4141K101 Datasheet PDF : 10 Pages
1 2 3 4 5 6 7 8 9 10
Housed varistors
ThermoFuse varistors, ETFV25 series
ETFV25
Reliability data
Test
Varistor voltage
Clamping voltage
Surge current derating,
8/20 µs
Surge current derating,
2 ms
Abnormal overvoltage
test
Test methods/conditions
Requirement
The voltage between two terminals with To meet the specified value
the specified measuring current applied
is called VV (1 mADC @ 0.2 ... 2 s).
The maximum voltage between two To meet the specified value
terminals with the specified standard
impulse current (8/20 µs) applied.
CECC 42 000, test C 2.1
100 surge currents (8/20 µs), unipolar,
interval 30 s, amplitude corresponding
to derating curve for 100 impulses at
20 µs
|V/V (1 mA)| 10%
(measured in direction of
surge current)
No visible damage
CECC 42 000, test C 2.1
|V/V (1 mA)| 10%
100 surge currents (2 ms), unipolar, (measured in direction of
interval 120 s, amplitude corresponding surge current)
to derating curve for 100 impulses at 2 No visible damage
ms
UL1449, limited current abnormal
overvoltage test. Apply a high AC
voltage to ThermoFuse varistor, the
amplitude of overvoltage and current
limit will be adopted from UL1449
general instruction in section 37. The
specimen will be tested on a softwood
surface covered with a double layer of
white tissue paper. The specimen is to
be loosely draped with a double layer
of cheesecloth.
The cheesecloth shall cover openings
where flame, molten or other particles
may be expelled as a result of the test.
The test result will be visually
inspected.
Any of these phenomena shall
not be observed, or this
specimen will be judged as
failed part.
1. Emission of flame, molten
metal, glowing or flaming
particles through any
openings (pre-existed or
created as a result of the
test) in the product.
2. Charring, glowing, or
flaming of the supporting
surface, tissue paper, or
cheesecloth.
3. Ignition of the enclosure.
4. Creation of any openings
in the enclosure that
result in accessibility of
live parts, when judged in
accordance with
accessibility of live parts,
UL1449 section 13.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 5 of 10

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]