DS7505
Digital Thermometer and Thermostat
IN THIS EXAMPLE, THE DS7505 IS CONFIGURED
TO HAVE A FAULT TOLERANCE OF 2.
TOS
TEMPERATURE
THYST
INACTIVE
O.S. OUTPUT—COMPARATOR MODE
ACTIVE
INACTIVE
O.S. OUTPUT—INTERRUPT MODE
ACTIVE
ASSUMES A READ
HAS OCCURED
CONVERSIONS
Figure 4. O.S. Output Operation Example
Interrupt Mode
In interrupt mode, the O.S. output first becomes active
when the measured temperature exceeds the TOS value
a consecutive number of times equal to the FT value in
the configuration register. Once activated, O.S. can only
be cleared by either putting the DS7505 into shutdown
mode or by reading from any register (temperature,
configuration, TOS, or THYST) on the device. Once O.S.
has been deactivated, it is only reactivated when the
measured temperature falls below the THYST value a
consecutive number of times equal to the FT value. Again,
O.S can only be cleared by putting the device into shut-
down mode or reading any register. Thus, this interrupt/
clear process is cyclical between TOS and THYST events
(i.e, TOS, clear, THYST, clear, TOS, clear, THYST, clear,
etc.). Thermostat interrupt mode operation with FT = 2 is
illustrated in Figure 4.