ATF1502AS(L)
DC and AC Operating Conditions
Operating Temperature (Ambient)
VCC (5V) Power Supply
DC Characteristics
Commercial
0°C - 70°C
5V ± 5%
Industrial
-40°C - 85°C
5V ± 10%
Symbol Parameter
Condition
Min
Typ
Max
IIL
Input or I/O Low
Leakage Current
VIN = VCC
-2
-10
IIH
Input or I/O High
Leakage Current
2
10
IOZ
Tri-state Output
Off-state Current
VO = VCC or GND
-40
40
ICC1
Power Supply Current, Standby VCC = Max Std Mode Com.
60
VIN = 0, VCC
Ind.
75
“L” Mode Com.
10
Ind.
10
ICC2
ICC3(2)
Power Supply Current,
Power-down Mode
Reduced-power Mode
Supply Current, Standby
VCC = Max
VIN = 0, VCC
VCC = Max
VIN = 0, VCC
“PD” Mode
Std Mode
Com.
Ind.
1
5
35
40
VIL
Input Low Voltage
VIH
Input High Voltage
VOL
Output Low Voltage (TTL)
-0.3
2.0
VIN = VIH or VIL
Com.
3.0
VCC = MIN, IOL = 12 mA
Ind.
0.8
VCCIO + 0.3
0.45
0.45
Output Low Voltage (CMOS)
VIN = VIH or VIL
Com.
0.2
VCC = MIN, IOL = 0.1 mA
Ind.
0.2
VOH
Notes:
Output High Voltage (TTL)
VIN = VIH or VIL
2.4
VCC = MIN, IOH = -4.0 mA
1. Not more than one output at a time should be shorted. Duration of short circuit test should not exceed 30 sec.
2. ICC3 refers to the current in the reduced-power mode when macrocell reduced-power is turned on.
Units
µA
µA
mA
mA
µA
µA
mA
mA
mA
V
V
V
V
V
V
13
0995K–PLD–6/05