APX9270
Application Information (Cont.)
HB Bias Output and Hall Input Signals
The IC outputs a 1.3V voltage on HB pin to provide bias
for the external hall element. The IC also has two pins
IN+ and IN- to receive the hall signals from the hall
element. The hall signals are very weak so the layout
tracks must be short and far away from those noise
sources to avoid noise coupling. The hall input amplifier
has 20mV hysteresis. Therefore, the recommended dif-
ferential hall input voltage should be more than 60mV.
CT Capacitor
The capacitor that is connected from CT pin to GND
determines the shutdown time and restart time.
Locked Detection Time = CCT (× VCT1 0.2V)
ICT1
( ) Restart Time = CCT × VCT1 VCT2
ICT1
( ) Shutdown Time = CCT × VCT1 VCT2
ICT2
where
CCT = CT pin capacitor
For example:
V =12V,
CC
CCT=1µF
Locked Detection Time = 1.545 s
Restart Time = 0.909 s
Shutdown Time = 9.091 s
The value of charge capacitor in the range of 0.47µF to
1µF is recommended.
FG Resistor
The value of the FG resistor could be decided by the
following equation
RFG = V6VREG VFG
IFG
For example:
V
6VREG
=
6V,
I
FG
=
5mA,
V
FG
=
0.2V,
R
FG
=
1.16k
The value of resistor in the range of 1kto 10kis
recommended.
Thermal Pad Consideration
The thermal pad on the bottom of the TSSOP-20P pack-
age should be soldered down to a copper pad on the
circuit board. Heat can be conducted away from the ther-
mal pad through the copper plane to ambient. If the cop-
per plane is not on the top surface of the circuit board, 8 to
10 vias of 13 mil or smaller in diameter should be used to
thermally couple the thermal pad to the bottom plane. For
good thermal conduction, the vias must be plated through
and solder filled. The copper plane is used to conduct
heat away from the thermal pad should be as large as
practical.
If the ambient temperature is higher than 25οC, a larger
copper plane or forced-air cooling will be required to keep
the APX9270 junction temperature below the thermal pro-
tection temperature (160οC).
Thermal Consideration
Refer to “Maximum Power Dissipation vs. Ambient
Temperature”, the IC is safe to operate below the curve
and it will cause the thermal protection if the operating
area is above the line. For example, T = 50οC, the SSOP-
A
20 package maximum power dissipation is about 0.95W.
Power dissipation can be calculated by the following
equation:
( ) PD = VCC VOUT1 VOUT2 ×IOUT + VCC ×ICC
For example:
When VCC = 12V, ICC = 6mA, IOUT = 300mA, VOUT1 = 11.66V,
VOUT2 = 0.13V, then PD = 0.213W
According the power dissipation issue, we could adapt
this SSOP-20 package.