DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ADT7466 Просмотр технического описания (PDF) - ON Semiconductor

Номер в каталоге
Компоненты Описание
производитель
ADT7466 Datasheet PDF : 48 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
ADT7466
If the address pointer register is known to already be at the
desired address, data can be read from the corresponding data
register without first writing to the address pointer register, so
the procedure in Figure 18 can be omitted.
1
9
1
9
SCL
SDA
1
START BY
MASTER
0
0
1
1
0
0
FRAME 1
SERIAL BUS ADDRESS BYTE
R/W
D7
ACK. BY
ADT7466
1
SCL (CONTINUED)
D6 D5 D4 D3 D2 D1 D0
FRAME 2
ADDRESS POINTER REGISTER BYTE
ACK. BY
ADT7466
9
SDA (CONTINUED)
D7 D6 D5 D4 D3 D2 D1 D0
FRAME 3 DATA BYTE
ACK. BY STOP BY
ADT7466 MASTER
Figure 17. Writing a Register Address to the Address Pointer Register, then Writing Data to the Selected Register
1
9
1
9
SCL
SDA
1
START BY
MASTER
0
0
1
1
0
0
FRAME 1
SERIAL BUS ADDRESS BYTE
R/W
D7
ACK. BY
ADT7466
D6 D5 D4 D3 D2 D1 D0
FRAME 2
ADDRESS POINTER REGISTER BYTE
ACK. BY STOP BY
ADT7466 MASTER
Figure 18. Writing to the Address Pointer Register Only
1
9
1
9
SCL
SDA
1
START BY
MASTER
0
0
1
1
0
0
FRAME 1
SERIAL BUS ADDRESS BYTE
R/W
D7
ACK. BY
ADT7466
D6 D5 D4 D3 D2 D1 D0
FRAME 2
ADDRESS POINTER REGISTER BYTE
NO ACK. BY STOP BY
MASTER MASTER
Figure 19. Reading Data from a Previously Selected Register
Although it is possible to read a data byte from a data register
without first writing to the address pointer register if the
address pointer register is already at the correct value, it is not
possible to write data to a register without writing to the address
pointer register, because the first data byte of a write is always
written to the address pointer register.
In addition to supporting the send byte and receive byte
protocols, the ADT7466 also supports the read byte protocol
(see the SMBus Specifications Rev. 1.1 for more information).
If it is required to perform several read or write operations in
succession, the master can send a repeat start condition instead
of a stop condition to begin a new operation.
Rev. 3 | Page 13 of 48 | www.onsemi.com

Share Link: 