ADM1029
expects to see a fan interfaced to it. It does not necessarily
mean that the fan is actually, physically, connected.
If a fan is installed, events such as a fault output and
hot-swapping of the fan can cause INT and CFAULT to be
asserted, unless they are masked for that particular event. If
a fan is not installed, but is still physically connected to the
ADM1029, these events will be ignored with respect to
asserting INT or CFAULT, but will still be reflected in the
corresponding Fan Status Register.
Setting Bit 0 indicates that Fan 1 is installed and is set to
1 at power-up by default. Setting Bit 1 indicates that Fan 2
is installed and depends on the state of Pin 18
(TMIN/INSTALL) at power-up.
DEFAULTS
LOCAL = 605C
REMOTE 1 = 705C
REMOTE 2 = 705C
CONFIGURE
TEMPERATURE LOW
LIMITS
LOCAL (REG 0X98)
REMOTE 1 (REG 0X99)
REMOTE 2 (REG 0X9A)
DEFAULTS
LOCAL = 805C
REMOTE 1 = 1005C
REMOTE 2 = 1005C
CONFIGURE
TEMPERATURE HIGH
LIMITS
LOCAL (REG 0X90)
REMOTE 1 (REG 0X91)
REMOTE 2 (REG 0X92)
CONFIGURE
TEMPERATURE FAULT
ACTION
LOCAL (REG 0X40)
REMOTE 1 (REG 0X41)
REMOTE 2 (REG 0X42)
CONFIGURE
TEMPERATURE COOLING
ACTION
LOCAL (REG 0X48)
REMOTE 1 (REG 0X49)
REMOTE 2 (REG 0X4A)
DEFAULTS
LOCAL = 05C
REMOTE 1 = 05C
REMOTE 2 = 05C
CONFIGURE
TEMPERATURE OFFSETS
LOCAL (REG 0X30)
REMOTE 1 (REG 0X31)
REMOTE 2 (REG 0X32)
MEASURE
TEMPERATURE
LOCAL (REG 0XA0)
REMOTE 1 (REG 0XA1)
REMOTE 2 (REG 0XA2)
BIT 0 = 1
BIT 1 = 1
BIT 2 = 1
BIT 3 = 0
BIT 3 = 1
BIT 4 = 1
BIT 5 = 1
BIT 6 = 1
BIT 7
ASSERT CFAULT ON OVER-TEMPERATURE
RUN FAN(S) ALARM SPEED ON OVER-TEMPERATURE
ASSERT INT ON OVER-TEMPERATURE
ALARM BELOW LOW TEMP LIMIT
ALARM ABOVE LOW TEMP LIMIT
ASSERT CFAULT WHEN LOW TEMP LIMIT CROSSED
RUN FAN ALARM SPEED ON UNDER-TEMPERATURE
ASSERT INT ON UNDER-TEMPERATURE
LATCHES A TEMPERATURE OUT-OF-LIMIT EVENT
7
6
5
4
3
2
1
0
IS
TEMPERATURE
>
HIGH LIMIT?
IS
TEMPERATURE
>
HIGH LIMIT?
YES
CFAULT
IS
TEMPERATURE
>
HIGH LIMIT?
YES
FANS RUN
ALARM SPEED
ALARM ABOVE
OR BELOW LOW
TEMP LIMIT?
YES
INT
0 = ALARM BELOW TEMP LIMIT
LOW TEMP LIMT
CROSSED?
YES
1 = ALARM ABOVE TEMP LIMIT
CFAULT
LOW TEMP LIMT
CROSSED?
YES
LOW TEMP LIMT
CROSSED?
FANS RUN ALARM SPEED
YES
INT
BIT 0 = 1
BIT 1 = 1
X
AUTOMATIC FAN SPEED CONTROL (SEE TABLE 15 LATER)
FAN 1 RUNS AT ALARM SPEED FOR OUT-OF-LIMIT TEMPERATURE EVENTS;
OTHERWISE, FAN 1 RUNS AT SPEED DETERMINED BY AUTOMATIC FAN CONTROL
FAN 2 RUNS AT ALARM SPEED FOR OUT-OF-LIMIT TEMPERATURE EVENTS;
OTHERWISE, FAN 2 RUNS AT SPEED DETERMINED BY AUTOMATIC FAN CONTROL
X
X
X
X
X
1
0
Figure 23. Temperature Sensing Flowchart