ADM1191
Parameter
A0 PIN, A1 PIN
Set Address to 00, VADRLOWV
Set Address to 01, RADRLOWZ
Min
Typ
0
80
120
Set Address to 10, IADRHIGHZ
−0.3
Set Address to 11, VADRHIGHV
2
Input Current for 00 Decode, IADRLOW
−40
−25
Input Current for 11 Decode, IADRHIGH
3
I2C TIMING
Low Level Input Voltage, VIL
High Level Input Voltage, VIH
0.7 VBUS
Low Level Output Voltage on SDA, VOL
Output Fall Time on SDA from VIHMIN to VILMAX
Maximum Width of Spikes Suppressed by
Input Filtering on SDA and SCL Pins
20 + 0.1 CBUS
50
Input Current, II, on SDA/SCL When Not
−10
Driving a Logic Low Output
Input Capacitance on SDA/SCL
5
SCL Clock Frequency, fSCL
Low Period of the SCL Clock
600
High Period of the SCL Clock
1300
Setup Time for Repeated Start Condition, tSU;STA 600
SDA Output Data Hold Time, tHD;DAT
100
Setup Time for a Stop Condition, tSU;STO
Bus Free Time Between a Stop and a Start
Condition, tBUF
Capacitive Load for Each Bus Line
600
1300
Max
Unit Conditions
0.8
V
Low state
160
kΩ Resistor to ground state, load pin with
specified resistance for 01 decode
+0.3
μA Open state, maximum load allowed
on the A0 pin or A1 pin for 10 decode
5.5
V
High state
μA
VADR = 0 V to 0.8 V
6
μA
VADR = 2.0 V to 5.5 V
0.3 VBUS V
V
0.4
V
250
ns
250
ns
IOL = 3 mA
CBUS = bus capacitance from SDA to GND
+10
μA
pF
400
kHz
ns
ns
ns
900
ns
ns
ns
400
pF
1 Monitoring accuracy is a measure of the error in a code that is read back for a particular voltage/current. This is a combination of amplifier error, reference error, ADC
error, and error in ADC full-scale code conversion factor.
2 This is an absolute value to be used when converting ADC codes to current readings; any inaccuracy in this value is factored into absolute current accuracy values (see
the specifications for the Current Sense Absolute Accuracy parameter).
3 These are absolute values to be used when converting ADC codes to voltage readings; any inaccuracy in these values is factored into voltage accuracy values (see the
specifications for the Voltage Sense Accuracy parameter).
4 Time between the receipt of the command byte and the actual ADC result being placed in the register.