Data Sheet
Table 28. ALM_CTRL Bit Descriptions
Bits
Description (Default = 0x0000)
15
Rate-of-change enable for Alarm 2 (1 = rate of change,
0 = static level).
[14:12] Alarm 2 source selection.
000 = disable.
001 = power supply output.
010 = gyroscope output.
011 = not used.
100 = not used.
101 = auxiliary ADC input.
110 = temperature output.
111 = not used.
11
Rate-of-change enable for Alarm 1 (1 = rate of change,
0 = static level).
[10:8] Alarm 1 source selection (same as for Alarm 2).
[7:5] Not used.
4
Comparison data filter setting (1 = filtered data, 0 =
unfiltered data).
3
Not used.
2
Alarm output enable (1 = enabled, 0 = disabled).
1
Alarm output polarity (1 = active high, 0 = active low).
0
Alarm output line select (1 = DIO2, 0 = DIO1).
Table 29. Alarm Configuration Example 1
DIN
Description
0xA922, 0xA817 ALM_CTRL = 0x2217.
Alarm 1 input = GYRO_OUT.
Alarm 2 input = GYRO_OUT.
Static level comparison, filtered data.
DIO2 output indicator, positive polarity.
0xA181, 0xA000 ALM_MAG1 = 0x8100.
Alarm 1 is true if GYRO_OUT > +18.755°/sec.
0xA33F, 0xA200 ALM_MAG2 = 0x3F00.
Alarm 2 is true if GYRO_OUT < −18.755°/sec.
ADIS16260/ADIS16265
Table 30. Alarm Configuration Example 2
DIN
Description
0xA9AA, 0xA804 ALM_CTRL = 0xAA04.
Alarm 1 input = GYRO_OUT.
Alarm 2 input = GYRO_OUT.
Rate-of-change comparison, unfiltered data.
DIO1 output indicator, negative polarity.
0xB601
SMPL_PRD = 0x0001.
Sample rate = 256 SPS.
0xA40A
ALM_SMPL1[7:0] = 0x000A.
Alarm 1 rate of change period = 3.906 ms.
0xA60A
ALM_SMPL2[7:0] = 0x000A.
Alarm 2 rate of change period = 3.906 ms.
0xA181, 0xA000 ALM_MAG1 = 0x8100.
Alarm 1 is true if GYRO_OUT changes more
than 18.755°/sec over a period of 3.906 ms.
0xA30F, 0xA200 ALM_MAG2 = 0x0F00.
Alarm 2 is true if GYRO_OUT changes less
than 18.755°/sec over a period of 3.906 ms.
PRODUCT IDENTIFICATION
Table 31 provides a summary of the registers that identify
the product: PROD_ID, which identifies the product type;
LOT_ID1 and LOT_ID2, the 32-bit lot identification code;
and SERIAL_NUM, which displays the 16-bit serial number.
All four registers are two bytes in length.
Table 31. Identification Registers
Register Name Address Description
LOT_ID1
0x52
Lot Identification Code 1
LOT_ID2
0x54
Lot Identification Code 2
PROD_ID
0x56
Product identification = 0x3F89 or
0x3F84
(0x3F89 = 16,265 decimal; 0x3F84 =
16,260 decimal)
SERIAL_NUM 0x58
Serial number