DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

AD811(2015) Просмотр технического описания (PDF) - Analog Devices

Номер в каталоге
Компоненты Описание
производитель
AD811
(Rev.:2015)
ADI
Analog Devices ADI
AD811 Datasheet PDF : 20 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Data Sheet
ABSOLUTE MAXIMUM RATINGS
Table 2.
Parameter
Supply Voltage
AD811JR Grade Only
Internal Power Dissipation
8-Lead PDIP Package
8-Lead CERDIP Package
8-Lead SOIC_N Package
16-Lead SOIC_W Package
20-Lead LCC Package
Output Short-Circuit Duration
Common-Mode Input Voltage
Differential Input Voltage
Storage Temperature Range (Q, E)
Storage Temperature Range (N, R)
Operating Temperature Range
AD811J
AD811A
AD811S
Lead Temperature Range
(Soldering 60 sec)
Rating
±18 V
±12 V
Observe Derating Curves
θJA = 90°C/ W
θJA = 110°C/W
θJA = 155°C/W
θJA = 85°C/W
θJA = 70°C/W
Observe Derating Curves
±VS
±6 V
−65°C to +150°C
−65°C to +125°C
0°C to +70°C
−40°C to +85°C
−55°C to +125°C
300°C
Stresses at or above those listed under Absolute Maximum
Ratings may cause permanent damage to the product. This is a
stress rating only; functional operation of the product at these
or any other conditions above those indicated in the operational
section of this specification is not implied. Operation beyond
the maximum operating conditions for extended periods may
affect product reliability.
AD811
MAXIMUM POWER DISSIPATION
The maximum power that can be safely dissipated by the AD811 is
limited by the associated rise in junction temperature. For the
plastic packages, the maximum safe junction temperature is 145°C.
For the CERDIP and LCC packages, the maximum junction tem-
perature is 175°C. If these maximums are exceeded momentarily,
proper circuit operation is restored as soon as the die tempera-
ture is reduced. Leaving the device in the overheated condition
for an extended period can result in device burnout. To ensure
proper operation, it is important to observe the derating curves
in Figure 21 and Figure 24.
While the AD811 is internally short-circuit protected, this may
not be sufficient to guarantee that the maximum junction tem-
perature is not exceeded under all conditions. An important
example is when the amplifier is driving a reverse-terminated
75 Ω cable and the cable’s far end is shorted to a power supply.
With power supplies of ±12 V (or less) at an ambient temperature
of +25°C or less, and the cable shorted to a supply rail, the
amplifier is not destroyed, even if this condition persists for
an extended period.
METALIZATION PHOTOGRAPH
Contact the factory for the latest dimensions.
V+
VOUT
7
6
0.0618
(1.57)
–INPUT 2
3 AD811
4
+INPUT
V–
0.098 (2.49)
Figure 4. Metalization Photograph
Dimensions Shown in Inches and (Millimeters)
ESD CAUTION
Rev. G | Page 5 of 20

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]