LCX029CRT Просмотр технического описания (PDF) - Sony Semiconductor

Номер в каталоге
Компоненты Описание
производитель
LCX029CRT
Sony
Sony Semiconductor Sony
LCX029CRT Datasheet PDF : 27 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
LCX029CRT
5. Flicker
Flicker (F) is given by formula (5). DC and AC (XGA/NTSC: 30Hz, rms, PAL: 25Hz, rms) components of the
panel output signal for gray rastermode are measured by a DC voltmeter and a spectrum analyzer in
System II.
{ } AC component
F [dB] = 20 log
...(5)
DC component
Each input signal voltage for gray raster mode
is given by Vsig = 7.5 ± V50 [V]
where: V50 is the signal amplitude which gives
50% of transmittance in V-T characteristics.
6. Image Retention Time
Apply the monoscope signal to the LCD panel for 60 minutes and then change this signal to the gray scale
of Vsig = 7.5 ± VAC (VAC: 3 to 4V). Judging by sight at the VAC that holds the maximum image retention,
measure the time till the residual image becomes indistinct.
Monoscope signal conditions:
Vsig = 7.5 ± 5.0 or ± 2.0 [V]
(shown in the right figure)
Vcom = 7.1V
5.0V
7.5V
Black level
2.0V
White level
2.0V
5.0V
0V
Vsig waveform
7. Cross Talk
Cross talk is determined by the luminance differences between adjacent areas represented by Wi' and
Wi (i = 1 to 4) around a black window (Vsig = 5.0V/1V).
W2 W1 W1'
W4
W2'
W4'
Cross talk value CTK = Wi' Wi × 100 [%]
Wi
W3 W3'
15