LA76835NM
Chroma Block Input Signals and Test Conditions
Unless otherwise specified, the following conditions apply when each measurement is made.
1. VIF, SIF blocks: No signal
2. Y input to pin 52:
Unless otherwise specified, the deflector must be locked to the synchronous signal when the 0 (IRE) signal and the
horizontal/vertical composite signal are entered.
3. C input: C IN (pin 54) input
4. Bus control conditions:
Set red and blue drives to DAC at which the Y-signal level of pins 18, 19 and 20 becomes as close to R = G = B as
possible. Assume here that Gamma Def. is 1 (default), Video SW=”1”, and C.Ext=”1”. Set the following conditions
unless otherwise specified.
5. Adjust an external X-tal of pin 46 so that the series capacity and resistor impedance (Z) become as follows:
Z=0deg @3.579545MHz±10Hz
-40±1deg@3.579545MHz
6. How to calculate the demodulation ratio and angle as follows:
B-Y axis angle = tan-1(B(0)/B(270))+270°
R-Y axis angle = tan-1(R(180)/R( 90))+90°
G-Y axis angle = tan-1(G(270)/G(180))+180°
R-Y axis
90°
180°
G(180)
R(90)
G(270)
R(180)
B(270)
B(0)
0°
B-Y axis
G-Y axis
270°
No.7962-15/50