6.4 MODULE 4 - Setpoint Output Parameters (4-SEtPt)
4-SEtPt
PARAMETER MENU
Pro
SEL
SP2 Only
SPt SEL SP2 Enb SPn ASN SPn ACt SPn tOUt SPn VAL SPn OUt SPn LIt
Setpoint
Select
Setpoint 2
Enable
Setpoint
Assignment
Setpoint
Output
Action
Setpoint
Output
Time-out
Setpoint
Value
Setpoint
Output Logic
Setpoint
Annunciator
SPn P-UP
Setpoint Output
Power-up
State
SPn tYPE
Setpoint
Boundary
Type
SPn StbY
Setpoint
Standby
Operation
SPn AUtO
Counter
Auto Reset
SP1 Only
SP1 OFF2
SP1 Output
Off at SP2
Output
SP2 Only
SP2 OFF1
SP2 Output
Off at SP1
Output
SPn rSt
Setpoint
Output Reset
with Manual
Reset
Backlight
Unit Only
SPn ChC
Change Display
Color with
Output State
The Setpoint Output Parameters are only active when an optional Setpoint
Output Module is installed in the meter. Some parameters in the menu will not
appear depending on the Setpoint Assignment and Setpoint Output Action. The
Setpoint Parameter Availability chart below illustrates this.
SETPOINT SELECT
SPt SEL
NO NO SP1 SP2
Select the Setpoint Output to be programmed, starting with Setpoint 1. The
"n" in the following parameters reflects the chosen Setpoint number. After
Setpoint 1 is completely programmed, the display returns to SPt SEL. Repeat
steps for Setpoint 2 if both Setpoints are used in the application.
Select NO to exit the Setpoint programming module. The number of Setpoints
available is dependent on the Setpoint option module installed.
SETPOINT 2 ENABLE (SP2 Only)
SP2 Enb
NO YES
NO
Select YES to enable Setpoint 2 and access the setup parameters. If NO is
selected, the unit returns to SPt SEL and Setpoint 2 is disabled.
SETPOINT OUTPUT ACTION
SPn ACt
LAtCH t-OUt bOUNd
LAtCH
The parameter selects the action of the Setpoint Output as described in the
chart. Boundary output action is not applicable for Counter B assignment.
SPT ACTION DESCRIPTION
LAtCH Latched Output Mode
t-OUt
bOUNd
Timed Output Mode
Boundary Mode
(High Acting Type)
Boundary Mode
(Low Acting Type)
OUTPUT ACTIVATES
When Count =
Setpoint
When Count =
Setpoint
When Count
Setpoint
When Count
Setpoint
OUTPUT DEACTIVATES
At Manual Reset
(if SPn rSt=YES)
After Setpoint
Output Time-Out
When Count
< Setpoint
When Count
> Setpoint
SETPOINT ASSIGNMENT
SPn ASN
Count A Count A Count b rAtE
Select the display to which the Setpoint is assigned.
SETPOINT PARAMETER AVAILABILITY
PARAMETER
DESCRIPTION
COUNTER ASSIGNMENT (A or B) *
TIMED OUT BOUNDARY LATCH
t-OUt bOUNd LAtCH
SPn tOUt Setpoint Output Time-out Value
Yes
No
No
SPn VAL Setpoint Value
Yes
Yes
Yes
SPn OUt Setpoint Output Logic
Yes
Yes
Yes
SPn LIt Setpoint Annunciator
Yes
Yes
Yes
SPn P-UP Setpoint Output Power-up State
No
No
Yes
SPn tYPE Setpoint Boundary Type
No
Yes
No
SPn StbY Standby Operation (Low acting only)
No
Yes
No
SPn AUtO Counter Auto Reset
Yes
No
Yes
SP1 OFF2 SP1 Output Off at SP2 (SP1 only)
Yes
No
Yes
SP2 OFF1 SP2 Output Off at SP1 (SP2 only)
Yes
No
Yes
SPn rSt Output Reset with Manual Reset
Yes
No
Yes
SPn ChC Change Display Color w/ Output State Yes
Yes
Yes
* BOUNDARY Setpoint Action not applicable for Counter B Assignment
RATE ASSIGNMENT
TIMED OUT BOUNDARY LATCH
t-OUt bOUNd LAtCH
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
No
No
No
Yes
No
Yes
Yes
Yes
Yes
11

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]