DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MAX7315 Просмотр технического описания (PDF) - Maxim Integrated

Номер в каталоге
Компоненты Описание
производитель
MAX7315 Datasheet PDF : 26 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
8-Port I/O Expander with LED Intensity
Control, Interrupt, and Hot-Insertion Protection
WRITE TO OUTPUT PORTS REGISTERS (BLINK PHASE 0 REGISTERS/BLINK PHASE 1 REGISTERS)
SCL 1 2 3 4 5 6 7 8 9
SLAVE ADDRESS
COMMAND BYTE
SDA S A6 A5 A4 A3 A2 A1 A0 0 A 0 0 0 0 0 0 0 1 A MSB
DATA1
LSB A MSB
DATA2
LSB A P
START CONDITION
P7–P0
R/W ACKNOWLEDGE FROM SLAVE
ACKNOWLEDGE FROM SLAVE
ACKNOWLEDGE FROM SLAVE
DATA1 VALID
tDV
tDV
STOP
CONDITION
DATA2 VALID
READ FROM INPUT PORTS REGISTERS
SCL 1 2 3 4 5 6 7 8
SLAVE ADDRESS
SDA S A6 A5 A4 A3 A2 A1 A0 1
9
COMMAND BYTE
A MSB
DATA1
LSB A MSB
DATA4
LSB NA P
START CONDITION
P7–P0
DATA1
R/W ACKNOWLEDGE FROM SLAVE
DATA2
tDH
DATA3
ACKNOWLEDGE FROM MASTER
DATA4
tDS
STOP CONDITION
NO ACKNOWLEDGE FROM
MASTER
INTERRUPT VALID/RESET
SCL 1 2 3 4 5 6 7 8 9
SLAVE ADDRESS
COMMAND BYTE
SDA S A6 A5 A4 A3 A2 A1 A0 1 A MSB
DATA2
LSB A MSB
DATA4
LSB NA P
START CONDITION
P7–P0
DATA1
R/W ACKNOWLEDGE FROM SLAVE
DATA2
ACKNOWLEDGE FROM MASTER
DATA3
STOP CONDITION
NO ACKNOWLEDGE FROM
MASTER
INT
tIV
tIR tIV
tIR
Figure 10. Read, Write, and Interrupt Timing Diagrams
Command Address Autoincrementing
The command address stored in the MAX7315 circu-
lates around grouped register functions after each data
byte is written or read (Table 2).
Device Reset
If a device reset input is needed, consider the
MAX7316. The MAX7316 includes a RST input, which
clears any transaction to or from the MAX7316 on the
serial interface and configures the internal registers to
the same state as a power-up reset.
Detailed Description
Initial Power-Up
On power-up all control registers are reset and the
MAX7315 enters standby mode (Table 3). Power-up
status makes all ports into inputs and disables both the
PWM oscillator and blink functionality.
Configuration Register
The configuration register is used to configure the PWM
intensity mode, interrupt, and blink behavior, operate
the INT/O8 output, and read back the interrupt status
(Table 4).
12 ______________________________________________________________________________________

Share Link: 