POWERLINE
DC/DC-Converter
RP15-S_DF
Series
Specifications (typical at nominal input and 25°C unless otherwise noted)
Output Voltage Accuracy (full Load and nominal Vin)
±1%
Minimum Load (see Note 1)
10% of FL
Line Regulation (LL-HL at full load)
±1%
Load Regulation (25% to 100% FL)
Single
±1%
Dual
±2%
Cross Regulation (asymmetrical load 25%/100% FL)
Ripple and Noise (20MHz bandwith)
Single
Dual
±5%
50mVp-p
75mVp-p
Temperature Coefficient
Transient Response (25% load step change)
Over Voltage Protection
3.3V
Zener diode clamp (only single)
5V
12V
15V
±0.02%/°C, max.
500µS
3.9V
6.2V
15V
18V
Over Load Protection (% of full load at nominal Vin)
Short Circuit Protection
150% typ
Hiccup, automatic recovery
Efficiency
see „Selection Guide“ table
Isolation Voltage
Isolation Resistance
Isolation Capacitance
1.600VDC min.
109 Ω min.
300pF max.
Operating Frequency
Approved to Safety Standards
Single
Dual
500kHz typ.
300kHz typ.
UL 1950, EN60950
Operating Temperature Range
-40°C to +85°C(with derating)
Maximum Case Temperature
+100°C
Storage Temperature Range
-55°C to +105°C
Thermal Impedance
Natural convection
Natural convection with Heat Sink
12°C/Watt
10°C/Watt
Thermal Shock
Vibration
MIL-STD-810D
10-55Hz, 2G, 30 Min. along X, Y and Z
Relative Humidity
5% to 95% RH
Case Material
Nickel-Coated copper
Base Material
Non-conductive black plastic
Potting Material
Conducted Emissions
Radiated Emissions
ESD
Radiated Immunity
Fast Transient
Surge
Conducted Immunity
EN55022
EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Epoxy (UL94-V0)
Level A
Level A
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
continued on next page
222
April-2005
www.recom-international.com