NB2304A
Table 8. SWITCHING CHARACTERISTICS FOR INDUSTRIAL TEMPERATURE DEVICES
(All parameters are specified with loaded outputs)
Parameter
Description
t1
Output Frequency
Test Conditions
30 pF load (all devices)
15 pF load (−1, −2)
t1
Duty Cycle = (t2 / t1) * 100
(all devices)
Measured at 1.4 V, FOUT v 66.66 MHz
30 pF load
Measured at 1.4 V, FOUT v 50 MHz
15 pF load
t3
Output Rise Time
(−1, −2)
Measured between 0.8 V and 2.0 V
30 pF load
Measured between 0.8 V and 2.0 V
15 pF load
Output Rise Time
(−1H)
t4
Output Fall Time
(−1, −2)
Measured between 0.8 V and 2.0 V
30 pF load
Measured between 2.0 V and 0.8 V
30 pF load
Measured between 2.0 V and 0.8 V
15 pF load
Output Fall Time
(−1H)
Measured between 2.0 V and 0.8 V
30 pF load
t5
Output−to−Output Skew on same Bank All outputs equally loaded
(−1, −2)
Output−to−Output Skew
(−1H)
Output Bank A−to−Output Bank B skew
(−1)
All outputs equally loaded
All outputs equally loaded
Output Bank A−to−Output Bank B skew All outputs equally loaded
(−2)
t6
Delay, REF Rising Edge to FBK Rising Measured at VDD/2
Edge
t7
Device−to−Device Skew
Measured at VDD/2 on the FBK pins of the
device
t8
Output Slew Rate
Measured between 0.8 V and 2.0 V using
Test Circuit #2
tJ
Cycle−to−Cycle Jitter
(−1, −1H)
Measured at 66.67 MHz, loaded outputs,
15 pF load
Measured at 66.67 MHz, loaded outputs,
30 pF load
Measured at 133.3 MHz, loaded outputs,
15 pF load
Cycle−to−Cycle Jitter
(−2)
Measured at 66.67 MHz, loaded outputs,
30 pF load
Measured at 66.67 MHz, loaded outputs,
15 pF load
tLOCK
PLL Lock Time
Stable power supply, valid clock presented
on REF and FBK pins
Min Typ Max
15
100
15
133.3
40.0 50.0 60.0
Unit
MHz
%
45.0 50.0 55.0
2.50 ns
1.50
1.50
2.50 ns
1.50
1.25
200
ps
200
200
400
0 ±250 ps
0 500
ps
1
V/ns
180
ps
200
100
400
ps
380
1.0
ms
http://onsemi.com
6