Electrical Specifications: F = 2.45 GHz, VCC = 3.3 V, VEN = 2.5 V, TA = 25°C, Z0 = 50 Ω
Parameter
Gain
Input Return Loss
Forward Isolation
P1dB
Supply Voltage
Bias Voltage
Test Conditions
VCC1, VCC2, VCC3
VEN
Units
dB
dB
dB
dBm
V
V
Min.
29
—
—
—
—
—
Typ.
31
9
50
23
3.3
2.5
Max.
33
—
—
—
—
—
Current
Idle
POUT = 16 dBm, Modulated3
POUT = 16 dBm, C.W.
mA
30
mA
—
mA
60
43
55
65
—
85
100
Off Current
Control Current
Harmonics
Duty Cycle
Linear Output Power
Detector Output
Detector Sensitivity
VEN = 0 V
VEN Current
2fo @ -15 dBm Input Power
3fo @ -15 dBm Input Power
DSS source; compliance with 802.11b
EVM=2.5%, OFDM, QAM-64, 54 Mbps
POUT = 16 dBm, C.W.
Up to POUT = 16 dBm
µA
—
3
20
mA
—
3
5
dBc
—
-26
—
dBc
—
-75
—
%
—
100
—
dBm
—
20
—
dBm
—
16
—
V
1.35
1.5
1.75
mV/dB
—
110
—
3. EVM=2.5%, OFDM, QAM-64, 54 Mbps.
Absolute Maximum Ratings 4,5
Parameter
Absolute Maximum
Input Power
+ 5 dBm
Operating Supply Voltage
+4.0 Volts
Operating Control Voltage
+3.0 Volts
Operating Temperature
Channel Temperature
Storage Temperature
-20°C to +85°C
+150°C
-40°C to +150°C
4. Exceeding any one or combination of these limits may cause
permanent damage to this device.
5. M/A-COM does not recommend sustained operation near
these survivability limits.
2
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.