L6360
4
Recommended operating conditions
Recommended operating conditions
Table 4. Recommended operating conditions
Symbol
Parameter
Test condition Min. Typ. Max. Unit
VCC
VH
fSCL
Rbias
TJ
Supply voltage
Linear regulator input voltage
SCL clock frequency
Precision resistance
Junction temperature
18
32.5 V
7
-
VCC
V
400 kHz
-0.1% 124 0.1% kΩ
-25
125 °C
Table 5.
Symbol
Thermal data
Parameter
Typ.
Unit
Rth j-case Thermal resistance, junction-to-case
Rth j-amb Thermal resistance, junction-to-ambient(1)
6
°C/W
50
°C/W
1. Mounted on FR4 PCB with 2 signal Cu layers and 2 power Cu layers interconnected through vias.
Doc ID 022817 Rev 2